GI Bioanalytics
Instruments available
| Instrument Name |
Type |
Location |
Floor/Room |
Pump |
Sampler |
Detector 1 |
Detector 2 |
| HPLC A |
HPLC |
MIT |
76-641 |
G7111B Quat Pump |
G7167A Multisampler, 576 sample capacity |
G7115A DAD |
NA |
| HPLC B |
LC/MS |
MIT |
76-641 |
G1311 Quat Pump |
G1367E Multisampler, 192 sample capacity |
G4212B DAD |
Agilent 6120 Quadrupole MS |
| HPLC C |
HPLC |
BWH |
5th Floor |
Quat pump |
Multisampler, 576 sample capacity |
DAD |
NA |
| HPLC D |
HPLC |
BWH |
5th Floor |
Quat pump |
Multisampler, 192 sample capacity |
DAD |
NA |
| HPLC E |
Normal Phase HPLC |
BWH |
5th Floor |
Quat pump |
Tray sampler, 100 sample capacity |
DAD |
NA |
| HPLC F |
HPLC |
BWH |
5th Floor |
Quat pump |
Multisampler, 768 sample capacity |
DAD |
NA |
| HPLC G |
HPLC |
BWH |
5th Floor |
Binary pump |
Multisampler, 576 sample capacity |
DAD |
NA |
| HPLC H |
HPLC |
BWH |
5th Floor |
Quat pump |
Multisampler, 576 sample capacity |
DAD |
NA |
| HPLC I |
LC/MS |
BWH |
2nd Floor |
Quat pump |
Tray sampler, 100 sample capacity |
DAD |
Agilent 6130B Quadrupole MS |
| HPLC J |
HPLC |
MIT |
5-029 |
Quat pump |
Tray sampler, 100 sample capacity |
DAD |
Agilent 6125B Quadrupole MS |
| Brigham Triple Quad |
LC/MS/MS |
BWH |
5th Floor |
Binary pump |
Multisampler, 960 sample capacity |
Agilent 6495B QQQ MS |
NA |
| QTOF |
LC/MS/MS |
BWH |
5th Floor |
Binary pump |
Multisampler, 192 sample capacity |
DAD |
Agilent 6550A QTOF |
| 2DLC-QTOF |
2D-LC/MS/MS |
BWH |
5th Floor |
Two binary pumps |
Multisampler, 576 sample capacity |
Agilent 6545 QTOF |
NA |
| MIT Triple Quad |
LC/MS/MS |
MIT |
76-610 |
Binary pump |
Multisampler, 192 sample capacity |
Agilent 6495A QQQ MS |
NA |
| ICP/MS |
Inductively Coupled Plasma MS, metals analysis |
BWH |
5th Floor |
- |
- |
Agilent 7700s |
NA |
| Cary 3500 UV-vis |
Optical analysis |
BWH |
5th Floor |
NA |
4 zone thermal control (0–100 C |
NA |
NA |
| Cary 8453 UV-vis |
Optical analysis |
BWH |
5th Floor |
NA |
Multizone thermal control (10–70 C |
NA |
NA |
| Cary 60 UV-vis |
Optical analysis |
BWH |
5th Floor |
NA |
18 channel cuvette statoin |
NA |
NA |
| Cary 630 FTIR |
Optical analysis |
BWH |
5th Floor |
NA |
NA |
NA |
NA |
| Cary Eclipse Fluorimeter |
Optical analysis |
BWH |
5th Floor |
NA |
NA |
NA |
NA |
| 6890N GC/FID |
GC |
BWH |
5th Floor |
NA |
Headspace autosampler |
FID |
Also FID |
| 7890B GC-MS/MS |
GC/MS/MS |
BWH |
5th Floor |
NA |
Liquid-only autosampler |
7010B QQQ MS |
NA |
| 7890B GC/MS |
GC/MS |
MIT |
5-029 |
NA |
Headspace autosampler |
FID and TCD |
5977 Quadrupole MS |
| ISCO 1 |
Normal phase prep/flash chromatograph |
BWH |
2nd Floor |
NA |
NA |
UV-Vis |
NA |
| ISCO 2 |
Normal and reversed phase prep |
BWH |
5th Floor |
NA |
NA |
UV-Vis |
NA |
| GPC1 |
Polymer analysis |
BWH |
5th Floor |
Quat pump, DMF or THF only |
100 vial sampler |
DAD |
RID |
| GPC2 |
Polymer analysis |
BWH |
5th Floor |
Quat pump, water |
100 vial sampler |
DAD |
RID |
| TA instruments DSC |
Thermal analysis |
BWH |
NA |
NA |
NA |
NA |
NA |
| TA instruments TGA |
Thermal analysis |
BWH |
NA |
NA |
NA |
NA |
NA |